Support
components including foundation and construction
methodology, cross members, welds, bolts,
brackets and bracing |
• |
Seat boards |
• |
Foot boards |
• |
Retraction mechanics |
• |
Electrical grounding |
• |
Expansion and retraction
function |
• |
Fencing |
• |
Press boxes |
• |
Entrance ramps |
• |
Aisle ways |
• |
Railings |
• |
Steps |
• |
American with Disability
Act (ADA) considerations |
|
The
following guidelines form the basis for
safe bleacher use and operation: |
|
• |
Inspect
for damage at least twice a year |
• |
Place inspection stickers
which indicate the date of inspection on
all bleachers |
• |
Open and close bleachers
evenly |
• |
Bleachers must be fully
extended when open |
• |
Only trained maintenance
personnel should operate bleachers |
• |
Never allow students
to operate bleachers or to climb on retracted
bleachers |
• |
Install all bleacher
guardrails |
• |
Read and follow the
manufacturer's instructions |
• |
Remember that improper
opening and closing can damage bleachers
and may result in a system collapse |
|
Structure
& Site conforms to the: |
|
• |
NFPA
102 Standard for Grandstands, Folding and
Telescopic Seating, Tents and Membrane Structures |
|
| An
inspection guideline for bleacher and grandstand
systems. |
|
| Additional
Info @ www.nfpa.org |
|